Temperature and Humidity Environmental Test Chambers are used for various types of testing such as prototype evaluation, research & development testing, production testing, accelerated stress testing, reliability testing, failure analysis, and any other application where environmental simulation is needed.

| Environmental Temperature and Humidity Chamber | |||||||||||||||
| Secifications ( at +20ºC room temp. Or+25ºC water temp with empty load) | |||||||||||||||
| Model | KMH-R series | KMH-L series | KMH-S series | ||||||||||||
| 150R | 225R | 408R | 800R | 1000R | 150L | 225L | 408L | 800L | 1000L | 225S | 408S | 800S | 1000S | ||
| Temp. range | -20ºC~150ºC | -40 ºC~+150ºC | -70ºC~+150ºC | ||||||||||||
| Interior sizel | W(mm) | 600 | 700 | 700 | 1000 | 1000 | 600 | 700 | 700 | 1000 | 1000 | 700 | 700 | 1000 | 1000 |
| H(mm) | 600 | 700 | 750 | 1000 | 1000 | 600 | 700 | 750 | 1000 | 1000 | 700 | 750 | 1000 | 1000 | |
| D(mm) | 460 | 480 | 800 | 800 | 1000 | 460 | 480 | 800 | 800 | 1000 | 480 | 800 | 800 | 1000 | |
| Exterior size | W(mm) | 880 | 980 | 980 | 1280 | 1280 | 880 | 980 | 980 | 1280 | 1280 | 980 | 980 | 1280 | 1280 |
| H(mm) | 1730 | 1890 | 1940 | 2160 | 2160 | 1730 | 1890 | 1940 | 2160 | 2160 | 1890 | 1940 | 2160 | 2160 | |
| D(mm) | 1400 | 1460 | 1740 | 1750 | 1950 | 1400 | 1460 | 1740 | 1750 | 1950 | 1460 | 1740 | 1750 | 1950 | |
| Power(KW) | 5.8 | 6 | 7.5 | 12.8 | 12.8 | 7.5 | 7.5 | 8.5 | 14.5 | 14.5 | 9.5 | 10.6 | 18.5 | 18.5 | |
| Weight(KG) | 240 | 280 | 400 | 500 | 580 | 250 | 300 | 420 | 530 | 600 | 330 | 450 | 550 | 650 | |
| Humidity uniformity | ±3.0%R.H | ±5.0%R.H | ±3.0%R.H | ±5.0%R.H | ±3.0%R.H | ±5.0%R.H | |||||||||
| Heat up time | -20ºC~+100ºC,within 35 min | -40ºC~+100ºC, within 45 min | -70ºC~+100ºC,within 60 min | ||||||||||||
| Pull down time | +20ºC~-20ºC, within 45 min | +20ºC~-40ºC , within 60 min | +20ºC~-70ºC,within 80 min | ||||||||||||
| Standard accessories | Sight window*1, cable port(portΦ50mm)*1, shelves*2, chamber lamp*1, power cable *2m | ||||||||||||||
| Safety device (standard) | No fuse breaker, over pressure\over heat and over current protection for compressor, | ||||||||||||||
| Over temp. protect, over load protect of blower, dry heat protection | |||||||||||||||
| Control System | Balanced Temperature & Humidity Control System | ||||||||||||||
| Refrigeration system | Air Cooled (Water Cooled Type is option) | ||||||||||||||
| Hermetic compressor,Single stage refrigeration system | |||||||||||||||
| CFC-Free refrigerant(HFC-507/HFC-23) | |||||||||||||||
| Controller | Panel:7-inch LCD Touch panel, Chinese or English display selectable | ||||||||||||||
| Operation model :Program or fix point running | |||||||||||||||
| Memory capacity :120programs,1200steps, | |||||||||||||||
| All repeat 999 cycles, part repeat 99 cycles | |||||||||||||||
| Humidity Range | 20~98%R.H | ||||||||||||||
| Temp. constancy | ±0.5ºC | ||||||||||||||
| Humidity constancy | ±2.5%R.H | ||||||||||||||
| Temp. uniformity | ±2.0ºC | ||||||||||||||
| Interior material | Stainless Steel Plate(SUS 304) | ||||||||||||||
| Exterior material | Baked Painting Steel Or Stainless steel(SUS304) | ||||||||||||||
| Insulation material | Rigid polyurethane Foam and Glass Fiber Wool | ||||||||||||||
| Ambient Temp. | +5ºC~+35ºC | ||||||||||||||
| Wiring method | AC 380±10%50Hz ,3 phase 4 wires +Ground Wires | ||||||||||||||
| Note: 1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available | |||||||||||||||